Four things to look at first
Whether a building can become a hotel can mostly be narrowed down from documents and maps, before anyone estimates renovation costs.
Zoning districts: where hotels and ryokans are allowed
Even where the zoning district allows a hotel or ryokan, an education district laid over it can rule one out.
| Zoning district | Hotel or ryokan |
|---|---|
| Category 1 and 2 low-rise exclusively residential | Not allowed |
| Category 1 and 2 mid/high-rise exclusively residential | Not allowed |
| Category 1 residential | Allowed up to 3,000 m² of total hotel or ryokan floor area |
| Category 2 residential, quasi-residential | Allowed |
| Neighborhood commercial, commercial | Allowed |
| Quasi-industrial | Allowed |
| Rural residential | Not allowed |
| Industrial, exclusively industrial | Not allowed |
We have not found official guidance that clearly states whether simple lodging counts as a "hotel or ryokan" under the Building Standards Act or the education district ordinance. If you plan simple lodging, check with the ward's building department as well.
Building confirmation: does the hotel part exceed 200 m²?


When all or part of a building is converted to a hotel or ryokan and the total floor area of that part exceeds 200 m², you must file a building confirmation application and obtain a certificate of confirmation (kakunin-zumi-sho). The threshold was raised from 100 m² to 200 m² on 25 June 2019. At exactly 200 m², no application is needed.
Total floor area of the part converted to a hotel or ryokan
Over 200 m²
- File a building confirmation application and obtain a certificate of confirmation (kakunin-zumi-sho)
- Meet the Building Standards Act and the Fire Service Act
200 m² or less
- No confirmation application is needed
- The building must still meet the Building Standards Act and the Fire Service Act
The Ministry of Land, Infrastructure, Transport and Tourism (MLIT) also explains that compliance with the standards has nothing to do with whether the procedure is required. Taito City, for example, makes a structure that complies with building-related laws a condition of the hotel business license, even for a change of use that needs no confirmation application.
A change to a "similar use" needs no confirmation application. Changing between hotel and ryokan counts as one; changing from an office or an apartment building does not.
| Original use | Similar use? | Confirmation application |
|---|---|---|
| Hotel or ryokan (changing one to the other) | Yes | Not needed |
| Office | No | Needed over 200 m² |
| Apartment building (condominiums and rental apartments) | No | Needed over 200 m² |
Since April 2025, renovating a house may need a confirmation application
From 1 April 2025, a major repair or major remodeling of a two-story wooden house requires a building confirmation application in advance, even if the part used as a hotel is 200 m² or less.
| Work | Counts? |
|---|---|
| Replacing a staircase | Yes |
| Fully renovating the roof | Yes |
| Renovating kitchens and bathrooms | No |
| Installing handrails | No |
Buildings without a certificate of inspection
A missing certificate of inspection (kensa-zumi-sho) does not by itself make a building illegal, but to convert it to a hotel you need to investigate whether the building as it stands complies with the law. MLIT's "Guidelines for surveying the current state of existing buildings" (5th edition, September 2026) set out how to do this. An architect or a designated confirmation and inspection body carries out the survey.
What the survey found
Confirmed to meet the standards in force when it was built
- Can be treated as "existing non-conforming" (kizon futekikaku), even where parts do not meet current standards
- A change of use still brings some provisions under current standards (Building Standards Act, Article 87(3))
Some parts cannot be confirmed
- Those parts need work to bring them up to current standards
The construction date cannot be established
- The whole building has to be brought up to current standards

The provisions that come under current standards on a change of use include fire resistance, daylighting and evacuation. Which provisions are relaxed for an existing non-conforming building differs from building to building, so check with an architect.
Tokyo's Building Safety Ordinance applies at any size
The Tokyo Building Safety Ordinance groups hotels, ryokans and simple lodging as "hotels etc." and adds extra standards. Shops and similar uses come under it above 200 m², but there is no floor area threshold for hotels etc.
| Total floor area used as hotels etc. | Length of site bordering a road |
|---|---|
| 500 m² or less | 4 m or more |
| Over 500 m², up to 1,000 m² | 6 m or more |
| Over 1,000 m², up to 2,000 m² | 8 m or more |
| Over 2,000 m² | 10 m or more |
- As a rule, hotels etc. cannot be built on a site that reaches the road only through a narrow access strip (a flag-shaped lot) (Article 10). There are exceptions, for example where the access strip is 10 m wide or more and the site is under 1,000 m².
- If the floor area of hotels etc. on the second floor exceeds 200 m², the building must be at least quasi-fire-resistant, and above 400 m² it must be fire-resistant (Article 10-5).
- Walls between guest rooms must be built to limit the sound that passes through them (Article 11-4).
- Guest rooms in simple lodging need a window facing a road or an "open space in front of windows" (madosaki kuchi) (Article 37).
An amendment in April 2025 also revised the provisions that relax requirements when the use of an existing building is changed. Check with an architect whether they apply to your building.
Facility standards for the hotel business
Separately from the building standards, the Hotel Business Act Enforcement Order sets standards for guest rooms and facilities.
| Item | Ryokan and hotel business | Simple lodging business |
|---|---|---|
| Guest room size | 7 m² or more per room (9 m² or more for rooms with beds) | Total guest room floor area of 33 m² or more. If guests are limited to fewer than 10, at least 3.3 m² × the number of guests |
| Front desk | A front desk at the entrance, or alternative equipment that allows identity checks | Not set by the Enforcement Order. Some wards require one by ordinance |
| Bunk beds | Not specified | About 1 m or more between upper and lower bunks |
| Toilets and washbasins | An appropriate number. The specific number is set by ward ordinance or detailed rules | An appropriate number. The specific number is set by ward ordinance or detailed rules |
- Toilets, as an example: Taito City's detailed rules require 1 toilet where the guest rooms without their own toilet hold 1 to 5 people in total, and 2 where they hold 6 to 10.
- If the site falls within roughly 100 m of a school or child welfare facility, equipment that stops people seeing into guest rooms from outside is also needed.
The licensing process is covered in our guide to the license when buying an operating hotel.
Fire equipment
The Fire Service Act treats hotels and ryokans as buildings where many people sleep. The equipment standards are stricter than for homes or offices, and this is where a change of use most often adds construction work.
| Equipment | When it is required |
|---|---|
| Automatic fire alarm system | Required regardless of total floor area (Fire Service Act Enforcement Order, Article 21) |
| Simpler automatic fire alarm system | Below 300 m² of total floor area, the simpler system for specified small-scale facilities can be used instead. An amendment on 23 July 2024 allowed its use in buildings with only one staircase, if conditions are met. In Tokyo, using it in an existing building requires an application before work starts |
| Fire extinguishers | Required at 150 m² or more of total floor area. Below 150 m², still needed on any floor that is the third floor or higher, or a basement, with a floor area of 50 m² or more. The Tokyo Fire Prevention Ordinance may require more |
| Exit lights | Required as a rule. They may be waived in buildings that are easy to evacuate, which the local fire station decides |
| Sprinklers | Required in buildings of 11 or more stories and in multi-story buildings with a total floor area of 6,000 m² or more, among other cases. As a rule, small buildings do not need them |
If only part of a building becomes a hotel, the whole building becomes a mixed-use property. At 300 m² or more of total floor area, the whole building generally needs an automatic fire alarm system. There are exceptions for small buildings, so check with the fire station.

A 2019 Fire and Disaster Management Agency leaflet says that, as a rule, the simple automatic fire alarm system cannot be installed in buildings of three or more stories. That information predates the 2024 amendment.
At 1,000 m² or more, barrier-free standards for guest rooms
If the total floor area of new construction or of the part being converted is 1,000 m² or more, the Tokyo Barrier-Free Building Ordinance applies its standards to every guest room other than wheelchair-accessible rooms (general guest rooms). The current standards cover buildings where work starts on or after 1 October 2023.
- Clear width of the guest room entrance
- 80 cm or more
- Clear width of the bathroom and toilet doors inside the room
- 75 cm or more
- Stairs or steps inside the guest room (except a tatami area)
- No steps
The 75 cm applies to rooms of 15 m² or more. For rooms under 15 m², it is 70 cm or more.
What to check, in order
Before paying for costly surveys or design work, check what the documents and maps can tell you, in order.
Check the zoning district and education district
Use the ward's city planning map. If it shows a hotel is "not allowed", you can stop there.
Collect the building's documents
Get the certificate of confirmation, certificate of inspection, drawings and certificates of registered matters from the seller.
Decide the floor area and scope of work
Whether the hotel part exceeds 200 m², and whether there will be a major renovation, decides whether a building confirmation application is needed.
Check road frontage and the Tokyo ordinance
Look at the length of road frontage, whether the site is a flag-shaped lot, and the second-floor area.
Consult the public health center and fire station in advance
Take the drawings and check the hotel business standards and fire equipment. This is also where you find out whether a school is nearby.
Ask an architect and a contractor for estimates
Once you know all this, have them estimate the scope and cost of the work.
The order of filings and inspections up to the license is explained in our guide to opening a hotel after you buy it.
Questions
Can a single condominium unit become a hotel?
Besides the zoning district, you need to check whether the building's management rules allow non-residential use, and how the change affects fire equipment for the whole building. Converting even one unit makes the whole building mixed-use, which can require equipment work that includes the other units. A change from an apartment building to a hotel is not a similar use, so a building confirmation application is also needed above 200 m².
If it is 200 m² or less, are no procedures needed?
No confirmation application is needed, but the standards of the Building Standards Act, the Fire Service Act and the Hotel Business Act still have to be met. The public health center checks that the building complies when you apply for the hotel business license.
Can a house become simple lodging?
If the zoning district and education district are not a problem, it can be considered. It must meet the total guest room floor area of 33 m² or more (at least 3.3 m² × the number of guests if there are fewer than 10), the open space in front of windows required by the Tokyo Building Safety Ordinance, and the automatic fire alarm standards. If it is a two-story wooden house and you carry out a major renovation such as replacing the staircase, a building confirmation application is also needed.
Should I avoid buying a building without a certificate of inspection?
You can buy it, but to convert it to a hotel, an architect's survey of its current state is needed to confirm that it complies with the law. Depending on the result, major work may be needed, so we recommend investigating before you sign the contract.